Operation

  • Single knob for setting the temperature from −5 to +15 °C
  • Switching hysteresis of approx. 1 K
  • Green LED: heating active (relay on)
  • Two red LEDs for sensor faults and device overheating
  • Relay switches off automatically in every fault state
  • ON/OFF switch on the circuit board

Connections & housing

  • Power supply 230 V AC / 50 Hz (L, N)
  • Switched output L′ / N for heating cables up to 16 A (approx. 3.6 kW)
  • External NTC 10 kΩ sensor, included
  • Three IP65 cable glands: M20, M25 and M16
  • IP65 ABS housing with transparent lid — setting and LEDs visible with the lid closed

Typical uses

Water pipesGutters & downpipesRamps & drivewaysUnheated rooms
WarningDisconnect the power supply before installing or opening the thermostat. Installation must be carried out by a qualified electrician. Protect the heating circuit with a circuit breaker (max. 16 A) and a 30 mA residual current device; switch loads above 16 A via an external contactor.
FPT-01 housing 100 × 100 × 70 mm with cable glands M16, M25, M20
Housing 100 × 100 × 70 mm · M16 sensor (top), M25 heating + M20 supply (bottom)
FPT-01 wiring diagram: supply L, N, heating cable L′, N, NTC sensor
Wiring — supply L/N, heating cable L′/N, NTC sensor (no polarity)

Terminals

1 – N (lower)Neutral – heating cable
2 – N (lower)Neutral – supply
3 – L′ (lower)Switched output to heating cable, max. 16 A
4 – L (lower)Live – supply 230 V AC
NTC, NTC (upper)External NTC 10 kΩ sensor, no polarity

Installation steps

  1. Loosen the 4 lid screws and remove the transparent lid.
  2. Lead the cables through the glands, connect them as in the wiring diagram and tighten the glands.
  3. Set the temperature with the knob and switch ON/OFF to ON.
  4. Refit the lid and tighten the 4 screws evenly so the housing stays sealed (IP65).

A) As a pipe thermostat

  1. Check the voltage and rated power of the heating circuit (max. 16 A).
  2. Fix the sensor to the pipe with aluminium tape, at least 1 m from valves and the pipe end, offset 90–120° from the heating cable.
  3. Insulate pipe, sensor and heating cable before putting the system into operation.

B) As an ambient thermostat

  1. Check the voltage and rated power of the heating circuit (max. 16 A).
  2. Place the sensor in the air where the area is coldest. Outdoors, shield it from direct sun and wind; indoors, do not put it under thermal insulation.

Setting the temperature

Set the desired temperature with the knob between −5 and +15 °C; the scale is marked in 5 °C steps. Setting and LEDs can be read through the transparent lid — to change the setting, open the lid. For frost protection of pipes, +3 to +5 °C is usually sufficient.

Function

When the sensor temperature drops below the set value, the relay switches on and the heating cable is supplied — the green ACTIVE LED lights up. Above the set temperature plus the hysteresis (approx. 1 K) the relay switches off. If a sensor fault or overheating is detected, the relay switches off regardless of the temperature and a red LED lights up.

FPT-01 setting knob from −5 to +15 °C with ERROR 1, ERROR 2 and ACTIVE LEDs
Setting knob and LED indicators

LED indicators

ACTIVEHeating on — temperature below the set value · relay on
ERROR 1NTC sensor not connected or sensor cable broken · relay off
ERROR 2NTC sensor short-circuited or device overheating · relay off

The ON/OFF switch on the left of the circuit board turns the thermostat off (relay and LEDs inactive). It does not disconnect the terminals from the mains.

Troubleshooting

  1. ERROR 1 lights up: check that the sensor is connected to the NTC terminals and the sensor cable is not damaged.
  2. ERROR 2 lights up: check the sensor cable for a short circuit. If the sensor is fine, the device is overheating — check the installation location and the load on the relay output.
  3. No heating and no LED although it is cold: check the power supply, the ON/OFF switch and the knob setting.

Electrical

Supply voltage230 V AC, 50/60 Hz
Power consumptionapprox. 1 VA
Switching output16 A / 250 V AC
Max. heating loadapprox. 3.6 kW
Setting range−5 to +15 °C
Hysteresisapprox. 1 K
Switching accuracy±2 K
SensorNTC 10 kΩ, included

Housing

MaterialABS, transparent lid
Protection classIP65
Dimensions100 × 100 × 70 mm
Cable glandsM20, M25, M16
Wire cross-sectionmax. 2.5 mm²
Ambient temperature−20 to +50 °C
Weightapprox. 400 g