Fan coil & heating controls

Fan coil control, without new cables.

Pamirel thermostats send their commands over a secure 868 MHz LoRa link to a DIN-rail actuator next to the fan coil — so the control unit goes wherever it suits the room. Need it wired instead, or frost protection for pipes and gutters? That's in the range too.

868 MHzLoRa wireless link
50 mRF range
1.5 yrson 3×AAA batteries
ModBusRTU for BMS
PCH-RF · wireless linkLive
CONTROL UNIT · WALL ACTUATOR · DIN RAIL 868 MHz LoRa up to 50 m
→ TX SET 22.5 °C · COOL · FAN AUTO
← ACK V3 ON · C OPEN
Wireless link
868 MHz LoRa
Fan coil systems
2-pipe / 4-pipe
Control unit power
3×AAA or 12 V
Central control
ModBus RTU

The range

Four controllers, every datasheet one click away.

Compare all →
PCH-RF-12V control unit next to its DIN-rail actuator
PCH-RF-12V

Wireless RF Thermostat, 12 V

Wall control unit and DIN-rail actuator linked over 868 MHz LoRa. Only 2 wires for power — or none with a local 12 V DC supply. LCD or bright LED display.

PCH-RF-AAA battery-powered control unit
PCH-RF-AAA

Wireless RF Thermostat, battery

The same LoRa system with a control unit running on 3×AAA batteries for about 1.5 years — no wiring at all between control unit and actuator.

DT-2005/U front panel with LED display and five buttons
DT-2005/U

Digital Room Thermostat, 230 V

Mains-powered fan coil thermostat for 2- and 4-pipe systems: 3 fan speeds plus auto, heating and cooling valves, LED display, window and day/night inputs.

FPT-01 frost protection thermostat in IP65 housing with transparent lid
FPT-01

Frost Protection Thermostat

Switches heating cables on pipes, gutters and ramps. One knob from −5 to +15 °C, 16 A relay, external NTC sensor, IP65 housing with a transparent lid.

How the PCH-RF system works

Two units, one radio link.

The control unit only measures and sends commands; the actuator next to the fan coil does the switching. That's why the control unit needs 2 wires at most — or none at all.

01 · Control unit
On the wall, in the room
LCD and 6 keys for temperature, mode and fan speed. Runs on 3×AAA (PCH-RF-AAA) or 12 V over 2 wires (PCH-RF-12V).
LoRa 868 MHz
up to 50 m
02 · Actuator unit
On the DIN rail
230 V supply. Executes the commands, reads the PT1000 and window inputs and talks ModBus RTU to a central system.
230 V · 0–10 V
outputs
03 · Fan coil
Fan and valves
  • V1 · V2 · V3 fan speeds
  • H · C heating/cooling valves
  • 0–10 V continuous control

Installation

Installed and paired in three steps.

The actuator goes on the DIN rail next to the fan coil, the control unit goes on the wall — and the two find each other over the air.

  • 01 Mount the actuator on the DIN rail and wire 230 V, fan speeds and valves
  • 02 Fix the control unit's mounting plate to the wall; insert batteries or connect 12 V
  • 03 Set a unique RF address (P25) and pair with the actuator's hidden button

Get in touch

Talk to us about a project or an order.

Planning a hotel, an office building or a single apartment? Have a question about a datasheet, wiring or bulk pricing? Write to us directly — we're happy to help you pick the right controller.